|
|
|
|
|
|
|
|
|
Products > SHOWA > Oil lubrication system > Volumetric-motorized pump units > LCB3 (TMS) Lubrication Unit |
|
|
|
|
|
LCB3 (TMS) Lubrication Unit |
|
- TMS compliant – volumetric type automatic pump unit
- Discharge frequency can be controlled by timer or impulse
- Array of functions and features to suit various lubrication system requirements
The LCB3 TMS model lubrication unit possesses a controller which complies to the TMS standards.
The unit’s operation (discharge frequency or intermittence) can be controlled by either an
intermittence timer or an impulse count timer and may also be controlled from an external source.
Possessing a pressure switch & float switch, effective lubrication management can be undertaken. |
|
Specifications |
MODEL CODE |
Intermittence
(Impulse or mins) |
Discharge Vol.
(L / minute) |
Discharge
Pressure |
Tank
Capacity
(L) |
Effective
Tank
Capacity (L) |
Viscosity
Range |
Warning
Triggers |
LCB301 |
2, 4, 6, 8, 16, 24,
32, 48, 64, 128
(Can be modified) |
0.1L – 50Hz
0.12L – 60Hz |
1.5MPa |
3.4 |
2 |
50~800
m㎡/s |
Pressure surge,
pressure loss,
low oil levels |
LCB302 |
5.5 |
4.4 |
LCB303 |
14.4 |
10.9 |
※Oil can be discharged by pressing the “Instant button”. The pump will continue to operate until the button is released.
MOTOR SPECIFICATION
Voltage & Freq. |
100V 50Hz |
100V 60Hz |
200V 50Hz |
200V 60Hz |
Current (A) |
1.6A |
1.3A |
0.9A |
0.7A |
Output & Poles |
17W × 2P |
Operation |
Max. 5mins with resting time of operation × 2 |
※E – type insulation
※E – type insulationSpecified intermittence can be increased by × 2, × 3 or × 4
|
Form code |
|
Drawing |
|
|
|
|
|
|
|
|
|
© copyright 2018. A.N.O. Equipment And Supply Co., Ltd. , All Rights Reserved. |
|
HOTLINE : 086-207-2000 |
A.N.O. Equipment And Supply Co., Ltd.
8/8 ซ.นวมินทร์ 74 แยก 3 - 7 - 1 แขวงรามอินทรา เขตคันนายาว กทม. 10230
Tel : 02-947-9318-20 / แฟกซ์ : 02-947-9317 |
|
|
|